Support
Support is available 5 business days a week (Monday – Friday) / 8 business hours (09:00 – 17:00 CET) in English language.
- Speech Platform 4
- Speech Platform 3 (legacy)
Support is provided only for the latest version of the Phonexia Speech
Platform 4 Virtual Appliance, which includes all recent bug fixes and
enhancements.
Older versions are no longer maintained, and support for them is available on a
very limited basis.
Please, include diagnostic data when reporting Speech Platform 4 issue.
Without diagnostic data, the support staff may not be able to help you with the
issue.
- GUI
- Command line
- Open Settings and then go to Diagnostic data section. If the system asks for a password, enter the password and click on Show diagnostic data button.
- Select the time range for which the diagnostic data should be collected.
The default is last 1 day, but you might want to select longer period, depending on how long ago the issue you are tracking down happened. - Click on Generate button and wait while the system collects the diagnostic data and generates the report.
- When the process is finished, the diagnostic data archive is ready for
download.
The file is namedva-report-YYYY-MM-DD_hh-mm-ss.zip, whereYYYY-MM-DD_hh-mm-ssis the date and time of report creation. - Then click on the Download button to download the report ZIP file.
Alternatively, click on the File Browser button to open the reports storage in File Browser and download the ZIP file from there (the reports storage may contain previously created reports, so make sure to select the correct one to download).
Create the diagnostics report
- Connect to the virtual appliance :
$ ssh phonexia@<virtual-appliance-ip>
- Run diagnostics script:
$ sudo /home/phonexia/scripts/run-diag-report.sh
The script collects all the information and creates a report ZIP archive
/data/reports/va-report-YYYY-MM-DD_hh-mm-ss.zip,
where YYYY-MM-DD_hh-mm-ss is the date and time of report creation.
Now, when the report ZIP archive is created, there are two ways of obtaining it - via command line terminal or via File Browser.
Transfer the diagnostics report to local machine
-
via command line terminal
- Use SCP in the terminal on your local machine (not on the Speech
Platform terminal!) to transfer the report ZIP archive to your local
machine:
wherescp phonexia@<virtual-appliance-ip>:/data/reports/va-report-YYYY-MM-DD_hh-mm-ss.zip "<target-drirectory>"
va-report-YYYY-MM-DD_hh-mm-ss.zipis the name of the created ZIP file"<target-directory>>"is the desired local directory where you want to save the ZIP archive
- Use SCP in the terminal on your local machine (not on the Speech
Platform terminal!) to transfer the report ZIP archive to your local
machine:
-
via File Browser
- Open web browser and navigate to
http://<virtual-appliance-ip>/filebrowser/files - In the File Browser, go to
reportsfolder and select the report ZIP archive (the reports storage may contain previously created reports, so make sure to select the correct one to download) - Start downloading by clicking the highlighted 'down pointing arrow' button in the upper right part of the screen.
- Depending on your browser settings, the ZIP file will either download directly to your downloads folder, or the browser will ask you to specify where to save the ZIP archive.
- Open web browser and navigate to
Verify downloaded file
Check that the va-report-YYYY-MM-DD_hh-mm-ss.zip file has been successfully
downloaded and can be opened.
If you have issue with Speech Engine, please include a report in the ticket, to help the support staff to resolve your issue faster:
- Go to the Speech Engine installation directory.
- Open command line/terminal (in Ubuntu Linux Right click + press E, in Windows type command in the address bar).
- Run
./phxadmin --report(Linux) orphxadmin.exe /report(Windows) - Zip the created report directory and attach the ZIP file to your issue description.
- The report functionality is not available in old SPE versions (3.10 and older).
Critical and minor issue definition
Major Issue
An issue that renders the product partially functional, the use of which in a production environment is substantially reduced. The issue contains an error that impairs the ability of the system to process a majority of audio files or audio streams, or that renders the setup and maintenance of the system inoperable.
Critical Issue
The system is inoperative, and it has a critical effect on the end user’s operations, which can’t be solved by the end user’s or partner’s IT/technical administrator. This condition is generally characterized by system instability and requires immediate correction. Phonexia’s software function is stopped due to its internal error, and it fails again on a different data input after Phonexia’s software restart. If the issue does not appear on the latest version of Phonexia’s software, it will not be considered a Critical Issue. A Critical Issue is being fixed on a best-effort basis, and a fixed version of the product is delivered within the next bug fix release or software update.
Minor Issue
Any scenario that does not fall under the Critical or Severe Issue definitions above.
The Product is still operable but contains issues occurring in a minority of audio files or audio streams or are of a minor nature.